Choice of Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Impacts Hemodynamics Differently According to Aortic Annular Size

Published:December 17, 2016DOI:https://doi.org/10.1016/j.amjcard.2016.11.044
      We sought to determine whether balloon-expandable valve (BEV) and self-expanding valve (SEV) affect valve hemodynamics differently according to native aortic annulus size. Transcatheter aortic valve replacement can achieve superior prosthetic valve hemodynamics compared with surgical aortic valve replacement, particularly in patients with small aortic annulus. One hundred ninety-three consecutive transcatheter aortic valve replacement patients were grouped into tertiles defined by computed tomography derived aortic annulus systolic perimeter. The predischarge echocardiogram was analyzed for prosthetic valve hemodynamics. Tertile perimeter cutoffs were 73 and 80 mm. STS score decreased as annulus size increased (7.8% vs 7.6% vs 6.0%, p ≤0.05 for small, medium, and large annulus, respectively). In patients with small aortic annulus, SEV was associated with significantly higher dimensionless index (0.64 vs 0.53, p = 0.02) and lower peak velocity (1.8 vs 2.4 m/sec, p <0.001) and a trend toward lower mean gradient (7.5 vs 10.0 mm Hg, p = 0.07) compared with BEV. These differences were attenuated and absent in patients with medium and large annulus, respectively. Few patients had moderate/severe paravalvular leak, with no association with valve type or annulus size. There was no difference in mortality between tertiles or valve type at 30 days or 1 year. There was no association between aortic annulus perimeter and 1-year mortality by univariate analysis (hazard ratio 1.00, 95% CI 0.95 to 1.05, p = 0.86) or multivariate analysis (hazard ratio 1.02, 95% CI 0.95 to 1.09, p = 0.60). In conclusion, SEV hemodynamics was superior to BEV in patients with small aortic annulus. This difference was diminished in patients with larger aortic annulus. This study highlights the importance of valve selection in patients with small aortic annulus.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to American Journal of Cardiology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Abdel-Wahab M.
        • Mehilli J.
        • Frerker C.
        • Neumann F.J.
        • Kurz T.
        • Tolg R.
        • Zachow D.
        • Guerra E.
        • Massberg S.
        • Schafer U.
        • El-Mawardy M.
        • Richardt G.
        CHOICE Investigators, Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial.
        JAMA. 2014; 311: 1503-1514
        • Rodes-Cabau J.
        • Pibarot P.
        • Suri R.M.
        • Kodali S.
        • Thourani V.H.
        • Szeto W.Y.
        • Svensson L.G.
        • Dumont E.
        • Xu K.
        • Hahn R.T.
        • Leon M.B.
        Impact of aortic annulus size on valve hemodynamics and clinical outcomes after transcatheter and surgical aortic valve replacement: insights from the PARTNER trial.
        Circ Cardiovasc Interv. 2014; 7: 701-711
        • Clavel M.A.
        • Webb J.G.
        • Pibarot P.
        • Altwegg L.
        • Dumont E.
        • Thompson C.
        • De Larochelliere R.
        • Doyle D.
        • Masson J.B.
        • Bergeron S.
        • Bertrand O.F.
        • Rodes-Cabau J.
        Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis.
        J Am Coll Cardiol. 2009; 53: 1883-1891
        • Kodali S.K.
        • Williams M.R.
        • Smith C.R.
        • Svensson L.G.
        • Webb J.G.
        • Makkar R.R.
        • Fontana G.P.
        • Dewey T.M.
        • Thourani V.H.
        • Pichard A.D.
        • Fischbein M.
        • Szeto W.Y.
        • Lim S.
        • Greason K.L.
        • Teirstein P.S.
        • Malaisrie S.C.
        • Douglas P.S.
        • Hahn R.T.
        • Whisenant B.
        • Zajarias A.
        • Wang D.
        • Akin J.J.
        • Anderson W.N.
        • Leon M.B.
        • Investigators P.T.
        Two-year outcomes after transcatheter or surgical aortic-valve replacement.
        N Engl J Med. 2012; 366: 1686-1695
        • Hahn R.T.
        • Pibarot P.
        • Stewart W.J.
        • Weissman N.J.
        • Gopalakrishnan D.
        • Keane M.G.
        • Anwaruddin S.
        • Wang Z.
        • Bilsker M.
        • Lindman B.R.
        • Herrmann H.C.
        • Kodali S.K.
        • Makkar R.
        • Thourani V.H.
        • Svensson L.G.
        • Akin J.J.
        • Anderson W.N.
        • Leon M.B.
        • Douglas P.S.
        Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis: a longitudinal study of echocardiography parameters in cohort A of the PARTNER trial (placement of aortic transcatheter valves).
        J Am Coll Cardiol. 2013; 61: 2514-2521
        • Dvir D.
        • Webb J.G.
        • Bleiziffer S.
        • Pasic M.
        • Waksman R.
        • Kodali S.
        • Barbanti M.
        • Latib A.
        • Schaefer U.
        • Rodes-Cabau J.
        • Treede H.
        • Piazza N.
        • Hildick-Smith D.
        • Himbert D.
        • Walther T.
        • Hengstenberg C.
        • Nissen H.
        • Bekeredjian R.
        • Presbitero P.
        • Ferrari E.
        • Segev A.
        • de Weger A.
        • Windecker S.
        • Moat N.E.
        • Napodano M.
        • Wilbring M.
        • Cerillo A.G.
        • Brecker S.
        • Tchetche D.
        • Lefevre T.
        • De Marco F.
        • Fiorina C.
        • Petronio A.S.
        • Teles R.C.
        • Testa L.
        • Laborde J.C.
        • Leon M.B.
        • Kornowski R.
        Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.
        JAMA. 2014; 312: 162-170
        • Abbasi M.
        • Azadani A.N.
        Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion.
        J Biomech. 2015; 48: 3672-3680
        • Azadani A.N.
        • Jaussaud N.
        • Matthews P.B.
        • Ge L.
        • Guy T.S.
        • Chuter T.A.
        • Tseng E.E.
        Valve-in-valve implantation using a novel supravalvular transcatheter aortic valve: proof of concept.
        Ann Thorac Surg. 2009; 88: 1864-1869
        • Zenses A.S.
        • Mitchell J.
        • Evin M.
        • Stanova V.
        • Obadia J.F.
        • Pibarot P.
        • Rieu R.
        In vitro study of valve-in-valve performance with the CoreValve self-expandable prosthesis implanted in different positions and sizes within the Trifecta surgical heart valve.
        Comput Methods Biomech Biomed Engin. 2015; 18: 2086-2087
        • Midha P.A.
        • Raghav V.
        • Condado J.F.
        • Arjunon S.
        • Uceda D.E.
        • Lerakis S.
        • Thourani V.H.
        • Babaliaros V.
        • Yoganathan A.P.
        How can we help a patient with a small failing bioprosthesis?: an in vitro case study.
        JACC Cardiovasc Interv. 2015; 8: 2026-2033
        • Kodali S.
        • Pibarot P.
        • Douglas P.S.
        • Williams M.
        • Xu K.
        • Thourani V.
        • Rihal C.S.
        • Zajarias A.
        • Doshi D.
        • Davidson M.
        • Tuzcu E.M.
        • Stewart W.
        • Weissman N.J.
        • Svensson L.
        • Greason K.
        • Maniar H.
        • Mack M.
        • Anwaruddin S.
        • Leon M.B.
        • Hahn R.T.
        Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes.
        Eur Heart J. 2015; 36: 449-456