Advertisement

Anatomic Correlates of a Normal Perfusion Scan Using 64-Slice Computed Tomographic Coronary Angiography

Published:November 23, 2007DOI:https://doi.org/10.1016/j.amjcard.2007.07.046
      Both myocardial perfusion imaging (MPI) and multislice computed tomography (MSCT) are currently used to detect coronary artery disease (CAD). However, MSCT permits early detection of atherosclerosis while myocardial perfusion is still normal. In addition, MPI results can be normal despite the presence of high-risk CAD (left main and balanced 3-vessel CAD). In this study, the range of anatomic findings using MSCT in patients with normal MPI results was evaluated. In 180 patients presenting with chest pain, MPI (with gated single-photon emission computed tomography) and 64-slice MSCT were performed. In patients with normal MPI results, prevalences of completely normal coronary arteries, nonobstructive CAD, and obstructive CAD were determined using MSCT. The occurrence of high-risk CAD, including left main and 3-vessel disease, was also evaluated. Normal MPI and adequate MSCT findings were obtained in 97 patients (54%; 50% women; average age 58 ± 12 years; 5% with known CAD). A total of 38 patients (39%) showed normal coronary anatomy, whereas nonsignificant and significant CAD were observed in 37 (38%) and 18 patients (19%), respectively. Importantly, only 4 patients (4%) presented with high-risk CAD using 64-slice MSCT, 2 with left main and 2 with 3-vessel disease. In conclusion, a normal MPI result can be associated with a wide range of anatomic observations and cannot exclude the presence of both nonobstructive and obstructive CAD. However, importantly, the prevalence of high-risk CAD was rare.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to American Journal of Cardiology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Ehara M.
        • Surmely J.F.
        • Kawai M.
        • Katoh O.
        • Matsubara T.
        • Terashima M.
        • Tsuchikane E.
        • Kinoshita Y.
        • Suzuki T.
        • Ito T.
        • et al.
        Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population—comparison with conventional invasive angiography.
        Circ J. 2006; 70: 564-571
        • Leber A.W.
        • Knez A.
        • von Ziegler F.
        • Becker A.
        • Nikolaou K.
        • Paul S.
        • Wintersperger B.
        • Reiser M.
        • Becker C.R.
        • Steinbeck G.
        • Boekstegers P.
        Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography—a comparative study with quantitative coronary angiography and intravascular ultrasound.
        J Am Coll Cardiol. 2005; 46: 147-154
        • Leschka S.
        • Alkadhi H.
        • Plass A.
        • Desbiolles L.
        • Grunenfelder J.
        • Marincek B.
        • Wildermuth S.
        Accuracy of MSCT coronary angiography with 64-slice technology: first experience.
        Eur Heart J. 2005; 26: 1482-1487
        • Mollet N.R.
        • Cademartiri F.
        • van Mieghem C.A.
        • Runza G.
        • McFadden E.P.
        • Baks T.
        • Serruys P.W.
        • Krestin G.P.
        • de Feyter P.J.
        High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography.
        Circulation. 2005; 112: 2318-2323
        • Raff G.L.
        • Gallagher M.J.
        • O’Neill W.
        • Goldstein J.A.
        Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography.
        J Am Coll Cardiol. 2005; 46: 552-557
        • Schuijf J.D.
        • Pundziute G.
        • Jukema J.W.
        • Lamb H.J.
        • van der Hoeven B.L.
        • de Roos A.
        • van der Wall E.E.
        • Bax J.J.
        Diagnostic accuracy of 64-slice multislice computed tomography in the noninvasive evaluation of significant coronary artery disease.
        Am J Cardiol. 2006; 98: 145-148
        • Hacker M.
        • Jakobs T.
        • Matthiesen F.
        • Vollmar C.
        • Nikolaou K.
        • Becker C.
        • Knez A.
        • Pfluger T.
        • Reiser M.
        • Hahn K.
        • Tiling R.
        Comparison of spiral multidetector CT angiography and myocardial perfusion imaging in the noninvasive detection of functionally relevant coronary artery lesions: first clinical experiences.
        J Nucl Med. 2005; 46: 1294-1300
        • Schuijf J.D.
        • Wijns W.
        • Jukema J.W.
        • Atsma D.E.
        • de Roos A.
        • Lamb H.J.
        • Stokkel M.P.
        • Dibbets-Schneider P.
        • Decramer I.
        • De Bondt P.
        • et al.
        The relationship between non-invasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging.
        J Am Coll Cardiol. 2006; 48: 2508-2514
        • Sharir T.
        • Berman D.S.
        • Waechter P.B.
        • Areeda J.
        • Kavanagh P.B.
        • Gerlach J.
        • Kang X.
        • Germano G.
        Quantitative analysis of regional motion and thickening by gated myocardial perfusion SPECT: normal heterogeneity and criteria for abnormality.
        J Nucl Med. 2001; 42: 1630-1638
        • Cerqueira M.D.
        • Weissman N.J.
        • Dilsizian V.
        • Jacobs A.K.
        • Kaul S.
        • Laskey W.K.
        • Pennell D.J.
        • Rumberger J.A.
        • Ryan T.
        • Verani M.S.
        Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart—a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.
        Circulation. 2002; 105: 539-542
        • Beeres S.L.
        • Bax J.J.
        • Dibbets P.
        • Stokkel M.P.
        • Zeppenfeld K.
        • Fibbe W.E.
        • van der Wall E.E.
        • Schalij M.J.
        • Atsma D.E.
        Effect of intramyocardial injection of autologous bone marrow-derived mononuclear cells on perfusion, function, and viability in patients with drug-refractory chronic ischemia.
        J Nucl Med. 2006; 47: 574-580
        • Berman D.S.
        • Wong N.D.
        • Gransar H.
        • Miranda-Peats R.
        • Dahlbeck J.
        • Hayes S.W.
        • Friedman J.D.
        • Kang X.
        • Polk D.
        • Hachamovitch R.
        • Shaw L.
        • Rozanski A.
        Relationship between stress-induced myocardial ischemia and atherosclerosis measured by coronary calcium tomography.
        J Am Coll Cardiol. 2004; 44: 923-930
        • Blumenthal R.S.
        • Becker D.M.
        • Yanek L.R.
        • Moy T.F.
        • Michos E.D.
        • Fishman E.K.
        • Becker L.C.
        Comparison of coronary calcium and stress myocardial perfusion imaging in apparently healthy siblings of individuals with premature coronary artery disease.
        Am J Cardiol. 2006; 97: 328-333
        • Høilund-Carslen P.F.
        • Johansen A.
        • Christensen H.W.
        • Vach W.
        • Moldrup M.
        • Bartram P.
        • Veje A.
        • Haghfelt T.
        Potential impact of myocardial perfusion scintigraphy as gatekeeper for invasive examination and treatment in patients with stable angina pectoris: observational study without post-test referral bias.
        Eur Heart J. 2006; 27: 29-34
        • Hacker M.
        • Jakobs T.
        • Hack N.
        • Nikolaou K.
        • Becker C.
        • von Ziegler F.
        • Knez A.
        • Konig A.
        • Klauss V.
        • Reiser M.
        • Hahn K.
        • Tiling R.
        Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina.
        Eur J Nucl Med Mol Imaging. 2007; 34: 4-10
        • Underwood S.R.
        • Anagnostopoulos C.
        • Cerqueira M.
        • Ell P.J.
        • Flint E.J.
        • Harbinson M.
        • Kelion A.D.
        • Al-Mohammad A.
        • Prvulovich E.M.
        • Shaw L.J.
        • Tweddel A.C.
        Myocardial perfusion scintigraphy: the evidence—a consensus conference organised by the British Cardiac Society, the British Nuclear Cardiology Society and the British Nuclear Medicine Society, endorsed by the Royal College of Physicians of London and the Royal College of Radiologists.
        Eur J Nucl Med Mol Imaging. 2004; 31: 261-291
        • Duvernoy C.S.
        • Ficaro E.P.
        • Karabajakian M.Z.
        • Rose P.A.
        • Corbett J.R.
        Improved detection of left main coronary artery disease with attenuation-corrected SPECT.
        J Nucl Cardiol. 2000; 7: 639-648
        • Hung G.U.
        • Chen C.P.
        • Yang K.T.
        Incremental value of ischemic stunning on the detection of severe and extensive coronary artery disease in dipyridamole Tl-201 gated myocardial perfusion imaging.
        Int J Cardiol. 2005; 105: 108-110
        • Williams K.A.
        • Schuster R.A.
        • Williams K.A.
        • Schneider C.M.
        • Pokharna H.K.
        Correct spatial normalization of myocardial perfusion SPECT improves detection of multivessel coronary artery disease.
        J Nucl Cardiol. 2003; 10: 353-360
        • Fujimoto S.
        • Wagatsuma K.
        • Uchida Y.
        • Nii H.
        • Nakano M.
        • Toda M.
        • Yamashina S.
        • Yamazaki J.
        Study of the predictors and lesion characteristics of ischemic heart disease patients with false negative results in stress myocardial perfusion single-photon emission tomography.
        Circ J. 2006; 70: 297-303