New electrocardiographic criteria for posterior wall acute myocardial ischemia validated by a percutaneous transluminal coronary angioplasty model of acute myocardial infarction

      Abstract

      The standard 12-lead electrocardiogram (ECG) fails to detect ST-segment elevation in patients with posterior wall acute myocardial ischemia. However, additional posterior leads V7-9 provide limited additional diagnostic information to the standard 12-lead ECG when an ischemic criterion of 1-mm ST elevation is used. No study is available to delineate the ischemic criteria in the posterior electrocardiographic leads. Continuous 15-lead ECGs (standard 12 lead + V7-9) were recorded in 53 subjects undergoing elective left circumflex coronary angioplasty (posterior ischemia model). ST amplitudes (J + 60 ms) at preangioplasty baseline were subtracted from maximal ST amplitudes during balloon occlusion to create a positive or negative change score (ΔST) for each of the 15 leads. During 53 left circumflex occlusions, 26 subjects (49%) had ΔST elevation of ≥1 mm and 24 subjects (45%) had ΔST elevation ranging from 0.5 to 0.95 mm in ≥1 posterior leads. Five subjects (9%) had ΔST elevation of ≥1 mm in the posterior leads without ΔST elevation anywhere in any of the 12 leads. The sensitivity in detecting myocardial ischemia using 15-lead ECGs (58%) was not statistically different from the standard 12-lead ECG (49%) (p = 0.06). Adjusting the ischemic criterion from 1 to 0.5 mm in V7-9 significantly improved the sensitivity from 49% in the 12-lead ECG to 94% in the 15-lead ECG (p = 0.000). In addition, 12 subjects (23%) had posterior ST-segment elevation without anterior ST-segment depression. Thus, posterior leads V7-9 contribute significant additional diagnostic information above and beyond the standard 12-lead ECG only when a new ischemic criterion of 0.5 mm instead of 1 mm ST elevation is applied to the posterior leads.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to American Journal of Cardiology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Mirvis D.M
        • Berson A.S
        • Goldberger A.L
        • Green L.S
        • Heger J.J
        • Hinohara T
        • Insel J
        • Krucoff M.W
        • Moncrief A
        • Selvester R.H
        • et al.
        Instrumentation and practice standards for electrocardiographic monitoring in special care units. A report for health professionals by a Task Force of the Council on Clinical Cardiology, American Heart Association.
        Circulation. 1989; 79: 464-471
        • Drew B.J
        • Wung S.F
        • Adams M.G
        • Pelter M.M
        Bedside diagnosis of myocardial ischemia with ST-segment monitoring technology.
        J Electrocardiol. 1998; 30: 157-165
        • Krucoff M.W
        • Pope J.E
        • Bottner R.K
        • Renzi R.H
        • Wagner G.S
        • Kent K.M
        Computer-assisted ST-segment monitoring.
        J Electrocardiol. 1987; 20: 15-21
        • Kulkarni A.U
        • Brown R
        • Ayoubi M
        • Banka V.S
        Clinical use of posterior electrocardiographic leads.
        Am Heart J. 1996; 131: 736-741
        • Khaw K
        • Moreyra A.E
        • Tannenbaum A.K
        • Hosler M.N
        • Brewer T.J
        • Agarwal J.B
        Improved detection of posterior myocardial wall ischemia with the 15-lead electrocardiogram.
        Am Heart J. 1999; 138: 934-940
        • Casas R.E
        • Marriott H.J
        • Glancy D.L
        Value of leads V7-V9 in diagnosing posterior wall acute myocardial infarction and other causes of tall R waves in V1-V2.
        Am J Cardiol. 1997; 80: 508-509
        • Agarwal J.B
        Routine use of a 15-lead electrocardiogram for patients presenting to the emergency department with chest pain.
        J Electrocardiol. 1998; 31: 172-177
        • Melendez L.J
        • Jones D.T
        • Salcedo J.R
        Usefulness of three additional electrocardiographic chest leads (V7, V8, and V9) in the diagnosis of acute myocardial infarction.
        Can Med Assoc J. 1978; 119: 745-748
        • Zalenski R.J
        • Cooke D
        • Rydman R
        • Sloan E.P
        • Murphy D.G
        Assessing the diagnostic value of an ECG containing leads V4R, V8, and V9.
        Ann Emerg Med. 1993; 22: 786-793
        • Zalenski R.J
        • Rydman R.J
        • Sloan E.P
        • Hahn K.H
        • Cooke D
        • Fagan J
        • Fligner D.J
        • Hessions W
        • Justis D
        • Kampe L.M
        • Shah S
        • Tucker J
        • Zwicke D
        Value of posterior and right ventricular leads in comparison to the standard 12-lead electrocardiogram in evaluation of ST-segment elevation in suspected acute myocardial infarction.
        Am J Cardiol. 1997; 79: 1579-1585
        • Oraii S
        • Maleki M
        • Tavakolian A.A
        • Eftekharzadeh M
        • Kamangar F
        • Mirhaji P
        Prevalence and outcome of ST-segment elevation in posterior electrocardiographic leads during acute myocardial infarction.
        J Electrocardiol. 1999; 32: 275-278
        • Shah A
        • Wagner G.S
        • Green C.L
        • Crater S.W
        • Sawchak S.T
        • Wildermann N.M
        • Mark D.B
        • Waugh R.A
        • Krucoff M.W
        Electrocardiographic differentiation of the ST-segment depression of acute myocardial injury due to the left circumflex artery occlusion from that of myocardial ischemia of nonocclusive etiologies.
        Am J Cardiol. 1997; 80: 512-513