      Abstract

      A thesis recently developed from a series of experiments on the isolated canine left ventricle is described. It is claimed that the ventricular pressure/volume ratio at end-systole is relatively insensitive to cardiac loading and varies greatly in response to changes in ventricular contractility. The clinical viability of this basic finding rests on the substitution of diameter for volume in this formulation. Diameter can be measured using a noninvasive ultrasonic technique in the clinic. Accordingly, end-systolic pressure/diameter ratio was studied in the isolated preparation and found to be similarly insensitive to loading conditions and sensitive to inotropic interventions.
      A further analysis of the pressure/diameter ratio in the ventricle of the conscious dog is in progress. In parallel with these studies, use of the pressure/diameter ratio to evaluate contractility in cardiac patients is being tested. The preliminary findings from conscious dogs and clinic patients are briefly discussed.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to American Journal of Cardiology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Guyton AC
        Circulatory Physiology: Cardiac Output and Its Regulation.
        in: WB Saunders, Philadelphia1973: 127-160
        • Braunwald E
        • Ross J
        • Sonnenblick EH
        Mechanisms of Contraction of the Normal and Failing Heart.
        in: second edition. Little, Brown, Boston1976: 130-165
        • Suga H
        • Sagawa K
        Instantaneous pressure-volume relationships and their ratio in the excised supported canine left ventricle.
        Circ Res. 1974; 35: 117-126
        • Beneken JEW
        • DeWit BA
        A physical approach to hemodynamic aspects of the human cardiovascular system.
        in: Reeve EB Guyton AC Physical Bases of Circulatory Transport: Regulation and Exchange. WB Saunders, Philadelphia1967: 1-45
        • Suga H
        • Sagawa K
        • Shoukas AA
        Load independence of the instantaneous pressure-volume ratio of the canine left ventricle and effects of epinephrine and heart rate on the ratio.
        Circ Res. 1973; 32: 314-322
        • Suga H
        • Yamakoshi K
        Effects of stroke volume and velocity of ejection on end-systolic pressure of canine left ventricle. Endsystolic volume clamping.
        Circ Res. 1977; 40: 445-450
        • Suga H
        • Sagawa K
        • Shoukas AA
        Carotid sinus baroreflex effects on instantaneous pressure-volume ratio of the canine left ventricle.
        J Physiol Soc Japan. 1974; 36: 106-107
        • Suga H
        • Sagawa K
        • Kostiuk DP
        Controls of ventricular contractility assessed by pressure-volume ratio, Emax.
        Cardiovasc Res. 1976; 10: 582-592
        • Suga H
        Theoretical analysis of a left ventricular pumping model based on the systolic time-vaying pressure-volume ratio.
        IEEE Trans Biomed Eng. 1971; 18: 47-55
        • Sandler H
        • Alderman E
        Determination of left ventricular size and shape.
        Circ Res. 1974; 34: 1-8
        • Suga H
        • Sagawa K
        Assessment of absolute volume from diameter of the intact canine left ventricular cavity.
        J Appl Physiol. 1974; 36: 496-499
        • Mahler F
        • Covell J
        • Ross J
        Systolic pressure-diameter relations in normal conscious dog.
        Cardiovasc Res. 1975; 9: 447-455
        • Weisfeldt M
        • Shoukas AA
        • Weiss JL
        • et al.
        Emax as a new contractility index in man (abstr).
        Circulation. 1976; 54: II-31