Comparison of observer performance with 16 mm cinefluorography and 70 mm camera fluorography in coronary arteriography

      This paper is only available as a PDF. To read, Please Download here.

      Abstract

      Clinical 16 mm cinefluorography and 70 mm camera fluorography were compared in 30 unselected patients undergoing coronary arteriography. Accuracy in detecting coronary arterial stenosis and collateral vessels and in assessing the degree of stenosis was similar with the two techniques. With both methods, there were significant inter- and intraobserver differences in estimating the degree of stenosis. These differences indicate that coronary arteriography is only a semiquantitative method for making decisions about treatment, prognosis and follow-up of patients. The use of more than one observer increases the likelihood that stenotic lesions will be detected. Interobserver variation in detecting collateral circulation is small.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to American Journal of Cardiology
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Boijsen E
        • Holm T
        • Kaude J
        Comparative angiographic studies using 70-mm intensifier fluorography and serial film changer.
        Medica Mundi. 1969; 14: 120-125
        • Hynes DM
        • Verel D
        • Moore RD
        • et al.
        Assessment of a technique for coronary arteriography using 70-mm film.
        Br J Radiol. 1969; 42: 736-743
        • Amiel M
        • Rubet A
        • Pinet F
        Intérêt et valeur de la photographie en format 70-mm de l'amplificateur de brillance au cours de l'artériographie coronaire sélective.
        Ann Radiol. 1971; 14 (Paris): 463-469
        • Groliman J
        • Gray R
        • Spiegler P
        • et al.
        105-mm serial photofluorography of the coronary arteries.
        Radiology. 1973; 108: 577-583
        • Judkins MP
        Selective coronary arteriography.
        in: Part 1. A percutaneous transfemoral technique. Radiology. 89. 1967: 815-824
        • Björk L
        Cineangiocardiography or full size angiocardiography?.
        in: A comparative study. Radiology. 86. 1966: 663-665
      1. Björk L, O'Keeffe A: Estimation of coronary artery stenosis. Some limitations of present methods. Invest Radiol, in press

        • Grondin CM
        • Campeau L
        • Dyrda I
        • et al.
        Discrepancies between cineangiographic and postmortem findings in patients with coronary artery disease and recent myocardial revascularization.
        Circulation. 1974; 49: 703-708
        • Birkelo CC
        • Chamberlain WE
        • Phelps PS
        • et al.
        Tuberculosis case finding: comparison of effectiveness of various roentgenographic and photofluorographic methods.
        JAMA. 1947; 133: 359-366
      2. Björk L, Erikson U, Hallstrom A: The videovolumeter. A new desk-top instrument for real time analysis of contrast agent changes in roentgen images. Invest Radiol, in press

        • Holman BL
        • Adams DF
        • Jewitt D
        • et al.
        Measuring regional myocardial blood flow with Xe and the anger camera.
        Radiology. 1974; 112: 99-107