American Journal of Cardiology
Volume 104, Issue 8 , Pages 1047-1051, 15 October 2009

Accuracy of Computed Tomographic Angiography for Stenosis Quantification Using Quantitative Coronary Angiography or Intravascular Ultrasound as the Gold Standard

Department of Cardiology, Washington Hospital Center, Washington, DC

Received 10 March 2009; received in revised form 20 May 2009; accepted 20 May 2009.

Computed tomographic angiography (CTA) is considered to have limited accuracy for quantifying exact percent diameter stenosis in coronary arteries. However, most studies evaluating CTA use quantitative coronary angiography (QCA) as the gold standard, a technique with its own limitations. We sought to determine whether CTA measurements of stenosis severity correlate better with intravascular ultrasound (IVUS) than with QCA. Luminal dimensions of 67 de novo coronary lesions were measured by CTA, IVUS, and QCA. IVUS was performed when lesion severity by angiography was equivocal. Mean percent diameter stenosis by QCA was 51 ± 9.8% and mean IVUS minimal luminal area was 3.8 ± 1.8 mm2. There was a moderate correlation between CTA minimal luminal area and IVUS minimal luminal area (r2 = 0.41, p <0.001), but no relation between CTA and QCA measurements of minimal luminal diameter (r2 = 0.01, p = 0.57) or diameter stenosis (r2 = 0.02, p = 0.31). There was also no relation between IVUS minimal luminal area and QCA diameter stenosis (r2 = 0.01, p = 0.50). When lesions with moderate or severe calcification were excluded, the correlation between CTA minimal luminal area and IVUS minimal luminal area was good (r2 = 0.68, p <0.001). In conclusion, in this cohort of patients with intermediate-grade lesions on cardiac catheterization, absolute measurements of stenosis severity on CTA correlated with IVUS but not with QCA. Our findings suggest that limitations of quantitative coronary angiography as a gold standard need to be considered in studies evaluating the accuracy of coronary CTA.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0002-9149(09)01175-8

doi:10.1016/j.amjcard.2009.05.052

American Journal of Cardiology
Volume 104, Issue 8 , Pages 1047-1051, 15 October 2009