« Previous
Next »
American Journal of Cardiology
Volume 104, Issue 3
, Pages 343-348
, 1 August 2009
Relation of Drug-Eluting Stent Strut Distribution to Stent Thrombosis in Coronary Arteries
References
- . Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003;349:1315–1323
- . Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation. 2003;108:788–794
- . Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA. 2005;293:2126–2130
- . Correlates and long-term outcomes of angiographically proven stent thrombosis with sirolimus- and paclitaxel-eluting stents. Circulation. 2006;113:1108–1113
- . Late angiographic stent thrombosis events with drug eluting stents. J Am Coll Cardiol. 2005;45:2088–2092
- . Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy. Lancet. 2004;364:1519–1521
- . Stent thrombosis after successful sirolimus-eluting stent implantation. Circulation. 2004;109:1930–1932
- . Drug-eluting stent thrombosis (Results from a pooled analysis including 10 randomized studies). J Am Coll Cardiol. 2005;45:954–959
- . Late thrombosis following treatment of in-stent restenosis with drug eluting stents after discontinuation of antiplatelet therapy. Catheter Cardiovasc Interv. 2005;65:520–524
- . Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the SIRIUS trial. J Am Coll Cardiol. 2004;43:1959–1963
- . Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol. 2005;45:995–998
- . Intravascular ultrasound parameters associated with stent thrombosis after drug-eluting stent deployment. Am J Cardiol. 2007;100:615–620
- . Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent (Should we be cautious?). Circulation. 2004;109:701–705
- . Predictors of edge stenosis following sirolimus-eluting stent deployment (a quantitative intravascular ultrasound analysis from the SIRIUS trial). Am J Cardiol. 2005;96:1251–1253
- . Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation. 2007;115:2426–2434
- . Fracture of a drug-eluting stent in the tibioperoneal trunk following bifurcation stenting. J Endovasc Ther. 2007;14:106–109
- . Acute coronary syndrome due to hinge movement of a bare-metal stent. Int J Cardiol. 2008;123:e64–e66
- . Sirolimus-eluting stent fracture with thrombus, visualization by optical coherence tomography. Eur Heart J. 2006;27:1389
- . Comparison of nonuniform strut distribution between two drug-eluting stent platforms. J Invasive Cardiol. 2007;19:244–246
- . Nonuniform strut distribution correlates with more neointimal hyperplasia after sirolimus-eluting stent implantation. Circulation. 2004;110:3430–3434
- . Volumetric intravascular ultrasound assessment of neointimal hyperplasia and nonuniform stent strut distribution in sirolimus-eluting stent restenosis. Am J Cardiol. 2006;98:1559–1562
- . Features and parameters of drug-eluting stent deployment discoverable by intravascular ultrasound. Am J Cardiol. 2007;100(suppl):26M–35M
- . American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS) (A report of the American College of Cardiology task force on clinical expert consensus documents). J Am Coll Cardiol. 2001;37:1478–1492
- . Predictors and outcomes of stent thrombosis (An intravascular ultrasound registry). Eur Heart J. 2002;23:124–132
- . Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol. 2007;100:628–630
- . Predictors of subacute stent thrombosis: results of a systematic intravascular ultrasound study. Circulation. 2003;108:43–47
- . Frequency and severity of plaque prolapse within Cypher and Taxus stents as determined by sequential intravascular ultrasound analysis. Am J Cardiol. 2006;98:1206–1211
- . Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol. 2006;48:193–202
- . Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J. 2007;28:961–967
- . Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation. 2007;115:2435–2441
PII: S0002-9149(09)00809-1
doi: 10.1016/j.amjcard.2009.03.047
© 2009 Elsevier Inc. All rights reserved.
« Previous
Next »
American Journal of Cardiology
Volume 104, Issue 3
, Pages 343-348
, 1 August 2009
