American Journal of Cardiology
Volume 103, Issue 4 , Pages 448-454 , 15 February 2009

Usefulness of Magnetocardiogram to Detect Unstable Angina Pectoris and Non-ST Elevation Myocardial Infarction

  • Hyun Kyoon Lim, PhD

      Affiliations

    • Korea Research Institute of Standards and Science, Daejeon, Korea
    • Corresponding Author InformationCorresponding author: Tel: 82-42-868-5775; fax: 82-42-868-5290
  • ,
  • Hyukchan Kwon, PhD

      Affiliations

    • Korea Research Institute of Standards and Science, Daejeon, Korea
  • ,
  • Namsik Chung, MD

      Affiliations

    • Yonsei University College of Medicine, Seoul, Korea
  • ,
  • Young-Guk Ko, MD

      Affiliations

    • Yonsei University College of Medicine, Seoul, Korea
  • ,
  • Jin-Mok Kim, MS

      Affiliations

    • Korea Research Institute of Standards and Science, Daejeon, Korea
  • ,
  • In-Seon Kim, PhD

      Affiliations

    • Korea Research Institute of Standards and Science, Daejeon, Korea
  • ,
  • Yong-Ki Park, PhD

      Affiliations

    • Korea Research Institute of Standards and Science, Daejeon, Korea

Received 23 July 2008 ,Revised 13 October 2008 ,Accepted 13 October 2008.

References 

  1. Koch H. Recent advances in magnetocardiography. J Electrocardiol. 2004;37(suppl):117–122
  2. Takala P, Hanninen H, Montonen J, Korhonen P, Makijarvi M, Nenonen J, et al. Heart rate adjustment of magnetic field map rotation in detection of myocardial ischemia in exercise magnetocardiography. Basic Res Cardiol. 2002;97:88–96
  3. Tolstrup K, Madsen BE, Ruiz JA, Greenwood SD, Camacho J, Siegel RJ, et al. Non-invasive resting magnetocardiographic imaging for the rapid detection of ischemia in subjects presenting with chest pain. Cardiology. 2006;106:270–276
  4. Park JW, Jung F. Qualitative and quantitative description of myocardial ischemia by means of magnetocardiography. Biomed Tech (Berl). 2004;49:267–273
  5. Hanninen H, Holmstrom M, Vesterinen P, Karvonen M, Vaananen H, Oikarinen L, et al. Magnetocardiographic assessment of healed myocardial infarction. Ann Noninvasive Electrocardiol. 2006;11:211–221
  6. Park JW, Hill PM, Chung N, Hugenholtz PG, Jung F. Magnetocardiography predicts coronary artery disease in patients with acute chest pain. Ann Noninvasive Electrocardiol. 2005;10:312–323
  7. Shiono J, Horigome H, Matsui A, Terada Y, Miyashita T, Tsukada K. Detection of repolarization abnormalities in patients with cardiomyopathy using current vector mapping technique on magnetocardiogram. Int J Cardiovasc Imaging. 2003;19:163–170
  8. On K, Watanabe S, Yamada S, Takeyasu N, Nakagawa Y, Nishina H, et al Integral value of JT interval in magnetocardiography is sensitive to coronary stenosis and improves soon after coronary revascularization. Circ J. 2007;71:1586–1592
  9. Nabipour I, Amiri M, Imami SR, Jahfari SM, Shafeiae E, Nosrati A, et al. The metabolic syndrome and nonfatal ischemic heart disease; a population-based study. Int J Cardiol. 2007;118:48–53
  10. Lim HK, Chung NS, Kim K, Ko YG, Kwon HC, Lee YH, et al Can magnetocardiography detect patients with non-ST-segment elevation myocardial infarction?. Ann Med. 2007;39:617–627
  11. Kim K, Lee YH, Kwon H, Kim JM, Kim IS, Park YK. Optimal sensor distribution for measuring the tangential field components in MCG. Neurol Clin Neurophysiol. 2004;2004:60
  12. Fenici R, Brisinda D, Meloni AM. Effects of filtering on computer-aided analysis for detection of chronic ischemic heart disease with unshielded rest magnetocardiographic mapping. Neurol Clin Neurophysiol. 2004;2004:7
  13. Takala P, Hanninen H, Montonen J, Makijarvi M, Nenonen J, Toivonen L, et al. Beat-to-beat analysis method for magnetocardiographic recordings during interventions. Phys Med Biol. 2001;46:975–982
  14. Lim HK, Chung N, Kim K, Ko YG, Kwon H, Lee YH, et al. Reproducibility of quantitative estimate of magnetocardiographic ventricular depolarization and repolarization parameters in healthy subjects and patients with coronary artery disease. Ann Biomed Eng. 2007;35:59–68
  15. Yan GX, Lankipalli RS, Burke JF, Musco S, Kowey PR. Ventricular repolarization components on the electrocardiogram: cellular basis and clinical significance. J Am Coll Cardiol. 2003;42:401–409
  16. Stinstra JG, Shome S, Hopenfeld B, MacLeod RS. Modelling passive cardiac conductivity during ischaemia. Med Biol Eng Comput. 2005;43:776–782
  17. Jeyaraj D, Wilson LD, Zhong J, Flask C, Saffitz JE, Deschenes I, et al. Mechanoelectrical feedback as novel mechanism of cardiac electrical remodeling. Circulation. 2007;115:3145–3155
  18. Koerselman J, van der GY, de Jaegere PP, Grobbee DE. Coronary collaterals: an important and underexposed aspect of coronary artery disease. Circulation. 2003;107:2507–2511
  19. Panting JR, Gatehouse PD, Yang GZ, Grothues F, Firmin DN, Collins P, et al. Abnormal subendocardial perfusion in cardiac syndrome X detected by cardiovascular magnetic resonance imaging. N Engl J Med. 2002;346:1948–1953
  20. White CS, Kuo D, Kelemen M, Jain V, Musk A, Zaidi E, et al. Chest pain evaluation in the emergency department: can MDCT provide a comprehensive evaluation?. AJR Am J Roentgenol. 2005;185:533–540
  21. Christenson RH, Azzazy HM. Biochemical markers of the acute coronary syndromes. Clin Chem. 1998;44:1855–1864

 This study was supported by a research grant from Korea Ministry of Science and Technology, Seoul, Korea.

PII: S0002-9149(08)01876-6

doi: 10.1016/j.amjcard.2008.10.013

American Journal of Cardiology
Volume 103, Issue 4 , Pages 448-454 , 15 February 2009