American Journal of Cardiology
Volume 102, Issue 10 , Pages 1352-1355, 15 November 2008

Management of Subacute and Delayed Right Ventricular Perforation With a Pacing or an Implantable Cardioverter-Defibrillator Lead

Received 19 May 2008; received in revised form 13 July 2008; accepted 13 July 2008. published online 15 September 2008.

The development of small-diameter active fixation pacing and implantable cardioverter-defibrillator leads may be associated with increased risk for delayed right ventricular perforation. The management of this unforeseen complication has been poorly described. Eleven successive patients referred for right ventricular subacute or delayed perforation (no evidence of lead perforation at the time of the procedure, perforation of the right ventricle diagnosed ≥5 days after implantation) were reviewed. The perforation was related to a pacing (n = 7) or an implantable cardioverter-defibrillator (n = 4) lead. The main symptoms were major dyspnea with pericardial effusion requiring emergency pericardial drainage (n = 3), inappropriate implantable cardioverter-defibrillator shock (n = 1), syncope (n = 2), abdominal pain (n = 1), mammary hematoma (n = 1), diaphragm stimulation (n = 1), and chest pain (n = 1). One patient was strictly asymptomatic. Signs of lead dysfunction were observed in all 11 patients. The diagnosis of lead perforation was confirmed by chest x-ray, echocardiography, or computed tomography. Surgery was directly performed in 1 patient with suspicion of digestive perforation. In the remaining 10 patients, the leads were removed by simple traction under fluoroscopic guidance in the operating room, with surgical backup support. The need for close monitoring was highlighted by the occurrence in 1 patient of tamponade requiring percutaneous pericardiocentesis and urgent surgical revision. The postoperative course of these patients was unremarkable. In conclusion, subacute ventricular perforation is a rare but potentially life threatening complication of lead implantation. In most patients, the leads can safely be removed under fluoroscopic guidance, with surgical backup support and close monitoring.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0002-9149(08)01185-5

doi:10.1016/j.amjcard.2008.07.025

American Journal of Cardiology
Volume 102, Issue 10 , Pages 1352-1355, 15 November 2008