American Journal of Cardiology
Volume 102, Issue 8 , Pages 988-993 , 15 October 2008

Comparison of 64-Slice Multidetector Computed Tomography With Spectral Analysis of Intravascular Ultrasound Backscatter Signals for Characterizations of Noncalcified Coronary Arterial Plaques

  • Byoung-Joo Choi, MD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Doo-Kyoung Kang, MD

      Affiliations

    • Department of Radiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Seung-Jea Tahk, MD, PhD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
    • Corresponding Author InformationCorresponding author: Tel: 82-31-219-5712; fax: 82-31-219-5708
  • ,
  • So-Yeon Choi, MD, PhD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Myeong-Ho Yoon, MD, PhD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Hong-Seok Lim, MD, PhD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Soo-Jin Kang, MD, PhD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Hyoung-Mo Yang, MD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Jin-Sun Park, MD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Mingri Zheng, MD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Gyo-Seung Hwang, MD, PhD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea
  • ,
  • Joon-Han Shin, MD

      Affiliations

    • Department of Cardiology, Ajou University School of Medicine, Suwon, Korea

Received 8 April 2008 ,Revised 23 May 2008 ,Accepted 23 May 2008.

References 

  1. Nishimura RA, Edwards WD, Warnes CA, Reeder GS, Holmes DR, Tajik AJ, et al. Intravascular ultrasound imaging: in vitro validation and pathologic correlation. J Am Coll Cardiol. 1990;16:145–154
  2. Nasu K, Tsuchikane E, Katoh O, Vince DG, Virmani R, Surmely JF, et al Accuracy of in vivo coronary plaque morphology assessment (A validation study of in vivo virtual histology compared with in vitro histopathology). J Am Coll Cardiol. 2006;47:2405–2412
  3. Rodriguez-Granillo GA, García-García HM, McFadden EP, Valgimigli M, Aoki J, de Feyter P, et al. In vivo intravascular ultrasound-derived thin-cap fibroatheroma detection using ultrasound radiofrequency data analysis. J Am Coll Cardiol. 2005;46:2038–2042
  4. Virmani R, Burke AP, Farb A, Kolodgie FD. Pathology of the vulnerable plaque. J Am Coll Cardiol. 2006;47(suppl):C13–C18
  5. Virmani R, Kolodgie FD, Burke AP, Farb A, Schwartz SM. Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. Arterioscler Thromb Vasc Biol. 2000;20:1262–1275
  6. Nikolaou K, Flohr T, Knez A, Rist C, Wintersperger B, Johnson T, et al. Advances in cardiac CT imaging: 64-slice scanner. Int J Cardiovasc Imaging. 2004;20:535–540
  7. Pohle K, Achenbach S, Macneill B, Ropers D, Ferencik M, Moselewski F, et al. Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: comparison to IVUS. Atherosclerosis. 2007;190:174–180
  8. Leber AW, Knez A, Becker A, Becker C, von Ziegler F, Nikolaou K, et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol. 2004;43:1241–1247
  9. Schroeder S, Kopp AF, Baumbach A, Meisner C, Kuettner A, Georg C, et al. Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol. 2001;37:1430–1435
  10. Becker CR, Nikolaou K, Muders M, Babaryka G, Crispin A, Schoepf UJ, et al. Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT. Eur Radiol. 2003;13:2094–2098
  11. Schroeder S, Flohr T, Kopp AF, Meisner C, Kuettner A, Herdeg C, et al. Accuracy of density measurements within plaques located in artificial coronary arteries by X-ray multislice CT: results of a phantom study. J Comput Assist Tomogr. 2001;25:900–906
  12. Cademartiri F, Mollet NR, Runza G, Bruining N, Hamers R, Somers P, et al. Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography. Eur Radiol. 2005;15:1426–1431

PII: S0002-9149(08)01012-6

doi: 10.1016/j.amjcard.2008.05.060

American Journal of Cardiology
Volume 102, Issue 8 , Pages 988-993 , 15 October 2008