« Previous
Next »
American Journal of Cardiology
Volume 98, Issue 3
, Pages 357-361
, 1 August 2006
Procedural Results and Outcomes After Extensive Stent Coverage With Drug-Eluting Stent Implantation in Single Coronary Lesions
References
- . Randomized study with the sirolimus-coated Bx velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions (a randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization) . N Engl J Med . 2002;346:1773–1780
- . Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery . N Engl J Med . 2003;349:1315–1323
- . TAXUS I (six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions) . Circulation . 2003;107:38–42
- . Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions . Circulation . 2003;108:788–794
- . A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease . N Engl J Med . 2004;350:221–231
- . Predictive factors of restenosis after coronary stent placement . J Am Coll Cardiol . 1997;30:1428–1436
- . Predictors of restenosis after coronary stent implantation . J Am Coll Cardiol . 1998;31:1291–1298
- . Angiographic and intravascular ultrasound predictors of in-stent restenosis . J Am Coll Cardiol . 1998;32:1630–1635
- Very long sirolimus-eluting stent implantation for de novo coronary lesions . Am J Cardiol . 2004;93:826–829
- . Multiple overlapping drug-eluting stents to treat diffuse disease of the left anterior descending coronary artery . J Am Coll Cardiol . 2005;45:1570–1573
- . Comparison of thrombosis and restenosis risk from stent length of sirolimus-eluting stents versus bare metal stents . Am J Cardiol . 2005;95:1140–1145
-
.
Stent thrombosis in the modern era
(a pooled analysis of multicenter coronary stent clinical trials)
.
Circulation
. 2001;103:1967–1971
- . Intraprocedural stent thrombosis during implantation of sirolimus-eluting stents . Circulation . 2004;109:2732–2736
- . Drug-eluting stent thrombosis (results from a pooled analysis including 10 randomized studies) . J Am Coll Cardiol . 2005;45:954–959
- . Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate (a multicenter, randomized study comparing two strategies—with and without intravascular ultrasound guidance) . J Am Coll Cardiol . 1998;32:320–328
- . Procedural results and late clinical outcomes after placement of three or more stents in single coronary lesions . Circulation . 1998;97:1355–1361
- . Procedural results and late clinical outcomes after percutaneous interventions using long (≥25 mm) versus short (<20 mm) stents . J Am Coll Cardiol . 2000;35:612–618
-
.
Impact of overlapping drug-eluting stents in patients undergoing percutaneous coronary intervention
.
Catheter Cardiovasc Interven
. 2006;67:595–599
- . Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents . Circulation . 2005;112:270–278
PII: S0002-9149(06)00721-1
doi: 10.1016/j.amjcard.2006.02.040
© 2006 Elsevier Inc. All rights reserved.
« Previous
Next »
American Journal of Cardiology
Volume 98, Issue 3
, Pages 357-361
, 1 August 2006