American Journal of Cardiology
Volume 91, Issue 6 , Pages 739-741 , 15 March 2003

Serial volumetric intravascular ultrasound assessment of native coronary artery versus saphenous vein grafts in-stent restenosis lesions after conventional catheter-based treatment

  • Javed M. Ahmed, MRCP

      Affiliations

    • Cardiovascular Research Institute, Washington Hospital Center, Washington, DC, USA
  • ,
  • Gary S. Mintz, MD

      Affiliations

    • Cardiovascular Research Foundation, New York, New York, USA
  • ,
  • Ron Waksman, MD

      Affiliations

    • Cardiovascular Research Institute, Washington Hospital Center, Washington, DC, USA
  • ,
  • Marco T. Castagna, MD

      Affiliations

    • Cardiovascular Research Institute, Washington Hospital Center, Washington, DC, USA
  • ,
  • Daniel Canos, MPH

      Affiliations

    • Cardiovascular Research Institute, Washington Hospital Center, Washington, DC, USA
  • ,
  • Lowell F. Satler, MD

      Affiliations

    • Cardiovascular Research Institute, Washington Hospital Center, Washington, DC, USA
  • ,
  • Kenneth M. Kent, MD

      Affiliations

    • Cardiovascular Research Institute, Washington Hospital Center, Washington, DC, USA
  • ,
  • Augusto D. Pichard, MD

      Affiliations

    • Cardiovascular Research Institute, Washington Hospital Center, Washington, DC, USA
  • ,
  • Neil J. Weissman, MD

      Affiliations

    • Cardiovascular Research Institute, Washington Hospital Center, Washington, DC, USA
    • Corresponding Author InformationDr. Weissman’s address is: Cardiovascular Research Institute, Washington Hospital Center, 110 Irving Street, NW, Suite 4B-1, Washington, DC 20010, USA.

Received 5 September 2002 ,Revised 21 November 2002 ,Accepted 21 November 2002.

References 

  1. Serruys PW, de Jaegere P, Kiemeneij F, Macaya M, Rutsch W, Heyndrickx G, et al  A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med. 1994;331:489–495
  2. Fischman DL, Leon MB, Baim D, Schatz RA, Savage MP, Penn I, et al  A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med. 1994;331:496–501
  3. Piana RN, Moscucci M, Cohen DJ, Kugelmass AD, Senerchia C, Kuntz RE, et al. Palmaz-Schatz stenting for treatment of focal vein graft stenosis (immediate results and long-term outcome). J Am Coll Cardiol. 1994;23:1296–1304
  4. Savage MP, Douglas JS, Fischman DL, Pepine CJ, King SB, Werner JA, et al  Stent placement compared balloon angioplasty for obstructed coronary bypass grafts. N Engl J Med. 1997;337:740–747
  5. Waksman R, White RL, Chan RC, Bass BG, Geirlach L, Mintz GS, et al  Intracoronary gamma radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis. Circulation. 2000;101:2165–2171
  6. Waksman R, Ajani AE, White RL, Chan RC, Satler LF, Kent KM, et al. Intravascular gamma radiation, for in-stent restenosis in saphenous vein bypass grafts. N Engl J Med. 2002;346:1194–1199
  7. Lansky AJ, Popma JJ. Quantitative angiography. In:  Topol EJ editors. Textbook of Interventional Cardiology. Philadelphia, PA: W.B. Saunders Co; 1999;p. 725–747
  8. Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, et al. Standards for the acquisition, measurement, and reporting of intravascular ultrasound studies (a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents). J Am Coll Cardiol. 2001;37:1478–1492
  9. Abizaid A, Mintz GS, Pichard AD, Kent KM, Satler LF, Walsh CL, et al. Clinical, intravascular ultrasound, and quantitative angiographic determinants of the coronary flow reserve before and after percutaneous transluminal coronary angioplasty. Am J Cardiol. 1998;82:423–428
  10. Nishioka T, Amanullah AM, Luo H, Berglund H, Kim CJ, Nagai T, et al  Clinical validation of intravascular ultrasound imaging for assessment of coronary stenosis severity (comparison with stress myocardial perfusion imaging). J Am Coll Cardiol. 1999;33:1870–1878
  11. Takagi A, Tsurumi Y, Ishii Y, Suzuki K, Kawana M, Kasanuki H. Clinical potential of intravascular ultrasound for physiological assessment of coronary stenosis (relationship between quantitative ultrasound tomography and pressure-derived fractional flow reserve). Circulation. 1999;100:250–255
  12. Mehran R, Mintz GS, Hong MK, Tio FO, Bramwell O, Brahimi A, et al. Validation of the in vivo intravascular ultrasound measurement of in-stent neointimal hyperplasia volumes. J Am Coll Cardiol. 1998;32:794–799
  13. Kuntz RE, Baim DS. Defining coronary restenosis. Newer clinical and angiographic paradigms. Circulation. 1993;88:1310–1323
  14. Hoffmann R, Mintz GS, Dussaillant GR, Popma JJ, Pichard AD, Satler LF, et al. Patterns and mechanisms of instent restenosis (a serial intravascular ultrasound study). Circulation. 1996;94:1247–1254
  15. Castagna MT, Mintz GS, Waksman R, Ahmed JM, Maehara A, Ajani AE, et al. Comparative efficacy of γ-irradiation for treatment of in-stent restenosis in saphenous vein graft versus native coronary artery in-stent restenosis. An intravascular ultrasound study. Circulation. 2001;104:3020–3022

PII: S0002-9149(02)03419-7

doi: 10.1016/S0002-9149(02)03419-7

American Journal of Cardiology
Volume 91, Issue 6 , Pages 739-741 , 15 March 2003